Scanning in the Enterprise Web application is still under development. You can configure a scanner only at this time. Scanning at this time can be performed with the companion application ITrack LX.
Enterprise LX defaults
pre/postable preamble = 126 = ~
postamble = 13 = Enter
Zebra DS2278
This section will cover how to setup a Zebra DS2278 Bluetooth Barcode Scanner to work with ISoft products on mobile devices.
Scanner Info
Important Features: Bluetooth, 14 hour+ battery life, 5ft drop, 36 month warranty, 123Scan app, SDKs for iOS, Android, Windows
Quick Start Guide
Android using Chrome
The fastest way to get started is to scan the appropriate barcode for your device type. Make sure your device is fully charged!
This model of scanner can scan from a high resolution monitor or screen.
Each of the barcodes below will change the defaults on your scanner. You will need to "forget" or "remove" the device in your Bluetooth settings and reconnect.
The below barcodes have the following settings: Prefix : Suffix $, HID features for iOS, Host: HID BT Classic
iOS using ITrack LX App
You do not need to set up this device as a keyboard wedge
You first need to install the Zebra iOS app:
https://apps.apple.com/us/app/zebra-scanner-control/id1034012069
Open that app and go to Connection Help > Pair DS2278.
Follow the onscreen instructions.
When finished, go back to the main screen and choose Connect
Tap on the DS2278 and choose Disconnect. This will disconnect it from the Zebra app so you can connect it to the ITrack LX app.
Go to the ITrack LX app and after a few seconds you should hear a connection beep from the scanner. Scanning in the ITrack LX app with the DS2278 should now work.
Charging the Scanner
The charging circuit on the scanner is capable of using as much current as possible based on the power source.
Preferred Method: use a BC1.2 Compliant Micro USB adapter to a wall outlet (higher current charging capability above 900 mA).
External Links
Honeywell
Please make sure the Chrome browser on the Honeywell is on Chrome v101 or higher so that the Teardown app is sized correctly.
Setting up a Honeywell Scanner
This section will cover how to setup a Honeywell ScanPal EDA71 to work with ISoft products on mobile devices.
https://www.honeywellaidc.com/products/computer-devices/tablet/scanpaleda71
On your Honeywell device, navigate to: Settings -> Honeywell Settings -> Scan Settings -> Internal Scanner -> Default profile -> Data Processing Settings.
Under Data Processing Settings, make sure the following settings are configured:
Wedge - Make sure this is Checked
Wedge Method - Keyboard
Prefix - None
Suffix - None
Wedge as keys - Make sure this field is empty
Enterprise LX Honeywell config info
A global database setting Scanner Mode (ambleMode,honeywell) needs to be set to honeywell
A user has to have logged into an ITrack LX app before the default settings are present.
The current default is ambleMode which may change in the future. The following query will let you check on the setting.
SELECT
`globalsettingvalue`.`settingid`
, `setting`.`location`
, `setting`.`name`
, `globalsettingvalue`.`value`
, `setting`.`defaultvalue`
, `setting`.`scope`
, `setting`.`settingtype`
, `value`=`defaultvalue` AS isdefault
FROM
`globalsettingvalue`
INNER JOIN `setting`
ON (`globalsettingvalue`.`settingid` = `setting`.`settingid`)
WHERE (`setting`.`name` = 'Scanner Mode (ambleMode,honeywell)');
Munbyn
Setting up a Munbyn Scanner
This section will cover how to setup a MUNBYN IPDA081/IPDA086 Mobile Data Terminal to work with ISoft products on mobile devices.
https://pos.munbyn.com/munbyn-ipda081-rfid-handheld-computer/
On the Munbyn scanner, swipe up to see apps, then tap on keyboardemulator.
On the Function page, make sure Enable Scanner is on.
On the AppSettings page, turn on Release key off scan if it is not already enabled.
Then scroll down to Process mode. Make sure it is set to keyboard input. Under End mark, none of the options should be checked.
Prefix/preamble and suffix/postamble for the device can be edited under Data Format. If using a test program that uses prefix/suffix, be sure that the prefix/suffix in the program and in the scanner setting app (keyboardemulator) are the same.
The postamble/suffix does not allow you to use Enter so you need to leave that blank and instead check the box under EndMark that says Enter.
Tera Scanner
To enable the trigger on the Tera scanner handle:
-
Go to the Scanner Config Page.
-
Disable the scanner.
-
Key in 293 on the scanner keypad.
-
Re-enable the scanner.
-
The scanner config page should look like the image below if it's set correctly.
Windows 11 Industrial Rugged Tablet
Two additional applications are required to use the scanner features. You will need the Honeywell Download Manager tool which will manage any subsequent Honeywell software downloads, then an app called SoftWedge for the configuration of scanner itself. Both parts can be downloaded from the same portal: Honeywell Downloads
To download the SoftWedge zip file you will need to navigate the Honeywell file system on the left when you open the link: Software > Barcode Scanners > Software > Tools and Utilities > Softwedge > Current.
-
Unzip the SoftWedge folder
-
Open and read the PDF instructions in the folder
-
Run
SoftWedge.exe, it will open in the system tray -
Open up SoftWedge and verify the port status is connected
-
enter
~as the Prefix -
enter
{ CR}as the Suffix -
Verify things are working by doing test scans in ITrack Configuration->Scanner->Test Scanner